LWS Sanitary Turbine Flow Meter
Detailed Product Description
Measurable Flow Rate Range and Pressure Level: (See table 1)
Table 1. Measurable Flow Rage Range and Pressure Rating
Nominal Diameter | Standard Flow Range (SFR) | Extended Flow Range (EFR) | Standard Pressure Rating | |
(mm) | (in.) | (m3/h) | (m3/h) | (MPa) |
4 | 0.15 | 0.04 to 0.25 | 0.04 to 0.4 | 1.0 Mpa |
6 | 0.25 | 0.1 to 0.6 | 0.06 to 0.6 | 1.0 Mpa |
10 | 0.4 | 0.2 to 1.2 | 0.15 to 1.5 | 1.0 Mpa |
15 | 0.5 | 0.6 to 6 | 0.4 to 8 | 1.0 Mpa |
20 | 0.75 | 0.8 to 8 | 0.45 to 9 | 1.0 Mpa |
25 | 1 | 1 to 10 | 0.5 to 10 | 1.0 Mpa |
32 | 1.25 | 1.5 to 15 | 0.8 to 15 | 1.0 Mpa |
40 | 1.5 | 2 to 20 | 1 to 30 | 1.0 Mpa |
50 | 2 | 4 to 40 | 2 to 40 | 1.0 Mpa |
Model Selection (See Table 2)
Table 2. Model Selection Guidance
Description (SFR: Standard Flow Range) | ||||||||
LWS- | / | / | / | / | / | / | ||
Nominal Diameter (mm) | 4 |
|
|
|
|
|
| 4mm; SFR: 0.04 to 0.25 m3/h |
6 | 6mm; SFR: 0.1 to 0.6 m3/h | |||||||
10 | 10mm; SFR: 0.2 to 1.2 m3/h | |||||||
15 | 15mm; SFR: 0.6 to 6 m3/h | |||||||
20 | 20mm; SFR: 0.8 to 8 m3/h | |||||||
25 | 25mm; SFR: 1 to 10 m3/h | |||||||
32 | 32mm; SFR: 1.5 to 15 m3/h | |||||||
40 | 40mm; SFR: 2 to 20 m3/h | |||||||
50 | 50mm; SFR:4 to 40 m3/h | |||||||
Type | N | Basic Type: +12V to +24V DC Power Supply; Pulse Output | ||||||
A | 4 to 20 mA current output | |||||||
B | Battery Power Supply with filed Display | |||||||
C | Field Display and 4 to 20 mA current output | |||||||
C1 | Field Display and RS485 | |||||||
C2 | Field Display and HART | |||||||
Accuracy Rating | 10 | ±1.0% of reading | ||||||
05 | ±0.5% of reading | |||||||
Measurable Range | S | Standard: Refer to table 1 | ||||||
E | Extended: Refer to table 1 | |||||||
Housing Material | S | 304 Stainless Steel | ||||||
L | 316 (L) Stainless Steel | |||||||
Explosion Rating |
| Blank: without Explosion Proof | ||||||
E | Explosion Proof: ExdIIBT6 |